LV 123 10.4.3 – Test: range of lower limited operating capability

LV 123 10.4.3 - Test: range of lower limited operating capability

The behavior in the range of lower limited operating capability shall be verified for each controlled HV component. The specification of Table “HV voltage levels” shall be used.

Operation with the maximum intended performance within the permissible deviations for the HV operating status B2 shall be verified in the range of lower limited operating capability.

Caratteristiche

Compliance with the HV operating status B2 shall be verified.

The operating behavior of the HV component shall be documented and verified.

The test shall be used to verify that the maximum intended performance or the HV operating status B1 is complied with again when the DC HV voltage falls within the range of unlimited operating capability again after a deviating characteristic.

Test criteria:

  • Maximum intended performance in accordance with the HV operating status B2; performance within permissible deviations
  • No fault memory entry
  • Automatic reestablishment of maximum intended performance and of the HV operating status B1 in the event of a return to the range of unlimited operating capability