LV 123 10.4.1 – Test: range of unlimited operating capability

LV 123 10.4.1 - Test: range of unlimited operating capability

The behavior in the range of unlimited operating capability shall be verified for each HV component. The specifications of Table “HV voltage levels” shall be used.

Operation with the maximum intended performance shall be verified in the range of unlimited operating capability.

Caratteristiche

Compliance with the HV operating status B1 shall be verified.

Test criteria:

  • Unlimited operating capability
  • Maximum intended performance in accordance with the HV operating status B1
  • No fault memory entry

La prova viene svolta con Netwave e il software net.control.